C32 ACERT Tier 3
C32 ACERT generator sets incorporate a separate circuit aftercooling system (SCAC) for all configurations. The primary advantage of the SCAC systsem is reduced aftercooler corrosion since no sea water circulates through the aftercooler. Many other improvements on these engines contribute to minimizing owning and operating costs. The EPA Tier 3, IMO II, EU Stage IIIA compliant ratings are available with heat exchanger or keel cooled options. Heat exchanger configurations have an optional front mounted sea water pump.
Minimum Rating
730 ekW (913 kVA)
Maximum Rating
940 ekW (1175 kVA)
Frequency
60hz
Specification
Value
Minimum Rating
730 ekW (913 kVA)
Maximum Rating
940 ekW (1175 kVA)
Frequency
60hz
Speed
1800 rpm
Emissions/Fuel Strategy
EPA Tier III
Specification
Value
Aspiration
Turbocharged and aftercooled
Bore
5.7 in
Stroke
6.38 in
Displacement
1959.0 inĀ³
Governor Type
Electronic
Fuel System
MEUI
Engine Model
Vee-12, 4-stroke-Cycle-Diesel
Specification
Value
Width
60.2 in
Height
65.6 in
Weight - Estimated
15721.0 lb
Length
162.8 in/4271 mm (minimum), 175.3 in/4452 mm (maximum)
Specification
Value
Excitation
Permanent magnet
Number of Poles
4
Number of Bearings
2 roller bearings
Number of Leads
6
Insulation
Class H
IP Rating
23
Voltage Regulator
CDVR
U.S. EPA Tier 3 compliant
Extensive service network of dealers; Unparalleled service from authorized marine dealers
Proven engine operating history; Performance iron with thousands of hours of validation testing for quality and durability
60 months standard warranty
Heat Exchanger or Keel Cooling; Heat exchanger configurations: optional front mounted sea water pump
Separate circuit aftercooling system (SCAC): no seawater circulating through the aftercooler